HPC-3000
▪ Hydrogen production capacity of cabinet B is 0.5Nm³, hydrogen storage capacity of cabinet C is 158.4kg
▪ Meet cross-season needs of families with 3~4 people
▪ Lithium batteries can provide 10-20kWh electricity per day
▪ In winter, Off-grid independent electricity can be realized, with 3000kWh electricity without light If all used for heating, with an air source heat pump, can provide over 12,000kWh heat energy
Functional Features
▪ Intelligent energy control strategy
▪ Supports both main power and backup power modes
▪ Independent building energy supply
▪ Support both on-grid and off-grid strategies
▪ Integrated health sports smart hardware (family spinning bike power generation access)
System Advantages
▪ Zero carbon emissions in the whole process
▪ High-density energy storage, small footprint (more than 1MWH, lithium battery 42 feet cabinet)
▪ High capacity energy storage, low cost (above 1MWH, lithium battery 150-200wRMB)
▪ Stable heat pump heat source, and increase efficiency by more than 50%
▪ Photovoltaic power generation 100% utilization, no waste electricity generation
▪ Power generation side multi-fusion advantages
▪ Strong expandability on the energy side (supporting electricity, hydrogen and heat)
Cabinet-A
Inverter Output | |
Rated Output Power |
10,000W |
Max.Peak Power |
15,000W |
Rated Output Voltage |
220V AC(Single phase) |
Load Capacity of Motors |
6HP |
Rated AC Frequency |
50/60Hz |
Parallel Capacity |
1-6units |
Overload |
After triggering the overload protection the inverter will resume output after 3 minutes, 5 consecutive overloads will switch off the output until the inverter is restarted. (102%<load<110%) ±10%: error and output shutdown after 5min; (110% < load < 125%) ±10%: error and output shutdown after 10s. Load > 125% ±10%: error reported and output switched off after 5s. |
Battery | |
Battery Type |
Li-ion |
Rated Battery Voltage |
48VDC |
Voltage Range |
40-60VDC |
Max.MPPT Charging Current |
200A |
Max.Mains/Generator Charging Current |
120A |
Max.Hybrid Charging Current |
200A |
PV Input | |
Num. of MPP Trackers |
2 |
Max.PV array power |
5500W+5500W |
Max.input Current |
22/22A |
Max.Voltage of Open Circuit |
500VDC+500VDC |
MPPT Voltage Range |
125-425VDC |
Mains / Generator Input |
|
Input Voltage Range |
90-275VAC |
Frequency Range |
50/60Hz |
Bypass Overload Current |
63A |
Efficiency | |
MPPT Tracking Efficiency |
99.9% |
Max. Battery Inverter Efficiency |
92% |
General | |
Dimension |
620*445*130mm |
Weight |
27kg |
Protection Degree |
IP20,Indoor Only |
Operating Temperature Range |
-10~55℃,>45℃ derated(14~131℉,>113℉ derated) |
Noise |
<60dB |
Cooling Method |
Internal Fan |
Warranty Cooling Method |
2Years |
Communication | |
Embedded Interfaces |
RS485 / CAN / USB / Dry contact |
External Modules (Optional) |
Wi-Fi / GPRS |
Cabinet-B
Hydrogen Production Unit | Hydrogen production capacity 0.5Nm³ |
1 hydrogen production module | |
Power input 220 V – 230 V AC, 50/60 Hz | |
Input pressure: 35bar | |
Electrolyte 1% KOH | |
Nominal power consumption: 4.8 kWh/Nm³ | |
Hydrogen output purity after drying>99.999% | |
Water tank volume 38.5 L | |
In-fluent conductivity requirements < 20 μs/cm (25 °C) | |
Required Inlet flow rate > 0.28 L/min Maximum outlet flow rate with 3.8 L/min |
Power Generation Unit | Water cooled PEM fuel cell system, with a rated output power of 10kW and an idle power of ≤ 2kW |
Working environment temperature -10-40 ℃, coolant conductivity ≤ 5us/cm | |
Voltage and current output: 222A | |
Hydrogen inlet pressure 6-10bar, hydrogen purity requirement>99.97%, hydrogen flow rate ≤ 250NL/min | |
Water heat exchange, Post- heat exchange temperature>50 ℃ |
Cabinet-C
Dimension |
2032*1625*2205mm |
Area |
3.302㎡ |
Weight |
about 5.4 tons |
Hydrogen Storage |
52.8kg |
Maximum Pressure |
350bar |
Buffer Tank |
4 pcs,200bar,70L/pcs |
Hydrogen Storage Cylinder Group |
20pcs,110L/pcs |
Product Certification |
Project security risk assessment、CE-PED、CE-MD、CE-LVD、CE-EMC |